Challenge deckSelect disturbance scenario

Beginner

Intermediate

Advanced

Gain notation

The same controller, written the way a control course does or the way a field panel does.

Adds a third controller (PIC-101) on the gas outlet valve. The loops become coupled: draining liquid enlarges the gas space and drops pressure.

Well
Playback speed
PID presets

Configure both controllers before starting. Gains are locked during the attempt.

SEP-101 horizontal separator with gas, oil, and water. True total level 0.0 percent; measured total level 0.0 percent. True interface 0.0 percent; measured interface 0.0 percent. Total inlet 0.0 cubic metres per hour; oil outlet 0.0 cubic metres per hour; water outlet 0.0 cubic metres per hour. Actual oil valve 0.0 percent; actual water valve 0.0 percent. Safety: Filling: low-level protection bypassed.

SEP-101 · engineering fallback

Separator process cutaway

Filling: low-level protection bypassed
GAS SPACEOIL INVENTORYWATER INVENTORYTOTAL INLET · Stopped / 0.0 m³/hOIL OUTLET · Stopped / 0.0 m³/hWATER OUTLET · Stopped / 0.0 m³/hTOTAL TRUE 0.0%MEASURED 0.0%INTERFACE TRUE 0.0%MEASURED 0.0%SEP-101 · THREE-PHASE INVENTORY
Total true
0.0%
Total measured
0.0%
Total SP
50.0%
Interface true
0.0%
Interface measured
0.0%
Interface SP
20.0%
Total inlet
Stopped / 0.0 m³/h
Oil outlet
Stopped / 0.0 m³/h
Water outlet
Stopped / 0.0 m³/h
Oil command
0.0%
Oil actual
0.0%
Water command
0.0%
Water actual
0.0%
Active safety
Filling: low-level protection bypassed

2D engineering fallback · process values and safety logic remain fully active.

LIC-101

Total level / oil valve

Ready to tune

More valve opening → more oil out → lower total level

Total level process value
0.0%
Total level measured value
0.0%
Total level setpoint
50.0%
Oil valve command
0.0%
Oil valve actual position
0.0%
P / I / D
0.0 / 0.0 / 0.0
Total level primary gains
4.0

Response strength. Range 0–10 dimensionless.

0.08

Offset removal. Range 0–0.3 s⁻¹.

8.0

Damping and anticipation. Range 0–30 s.

Advanced settings
Total level advanced settings
IIC-101

Interface / water valve

Ready to tune

More valve opening → more water out → lower interface

Interface process value
0.0%
Interface measured value
0.0%
Interface setpoint
20.0%
Water valve command
0.0%
Water valve actual position
0.0%
P / I / D
0.0 / 0.0 / 0.0
Interface primary gains
4.0

Response strength. Range 0–10 dimensionless.

0.08

Offset removal. Range 0–0.3 s⁻¹.

8.0

Damping and anticipation. Range 0–30 s.

Advanced settings
Interface advanced settings
Total level0.0%0 mm of liquid · 900 mm to high alarm
Oil/water interface0.0%MAE 0.0% · low 0.0%
Oil valve LV-1010.0%Command 0.0% · travel 0.0%
Water valve WV-1010.0%Command 0.0% · travel 0.0%
Safety envelopeFilling: low-level protection bypassedTotal outside 0.0 s · interface 0.0 s
Control note

Low error is only half the job: watch actual valve travel and saturation too.

Run details
Deterministic seed
1002
Residence time
—
FIXED STEP 0.05 sCLIENT-SIDE PHYSICSNO RUNTIME AI

Coupled oil/water inventories · simplified hydraulics · educational use only