Research Lab
Replay real research runs
Recorded runs from eng_dacs, a separate research simulator, replayed in your browser. Nothing is simulated here: every frame comes from a published, verified trace.
Experiments
Reading the published index…
- C2Pending
Deployed PID versus a SIMC tuning on the interface loop
CONFIRMATORY3 seedsSynthetic, uncalibrated- Question
- Does one literature tuning (SIMC, τc 120 s, with a 10 s PV filter) settle LIC-103 interface setpoint steps faster than the deployed PID, on new seeds and scenarios?
- Compared
- LIC-103 under the deployed PID and under the SIMC design, same scenario and seed, +5 % interface setpoint step, 900 s window.
Confirmatory replication with frozen criteria and three new seeds. The design settles fast in 21 of 24 steps; at the low-water-flow scenario pi_1p5 it is classed saturated, because LCV-103 works almost on its seat.
Source and method
eng_dacs/docs/simulation/controllability_campaigns.md§9.6 (private repository)eng_dacs/experiments/envelope/config/control_c2_water_replication.yaml§header (pre-registration) (private repository)
Not exported yet: no trajectory is shown in its place. - C2Pending
A 20 s actuator lag on LCV-102, four hours
EXPLORATORY1 seedSynthetic, uncalibrated- Question
- With a 20 s first-order lag on the oil dump valve LCV-102, does the loop stay in band over 4 h under M6 B and under the C2 designs (c2simc)?
- Compared
- M6 B against c2simc at the high_rate scenario, seed 7100, LCV-102 actuator lag 20 s armed at the start of a 4 h hold.
Exploratory, one seed, uncalibrated simulator. M6 B leaves the total-level band 12,415 s into the hold (3.4 h); c2simc stays in band for the 4 h with a damped oscillation.
Source and method
eng_dacs/docs/simulation/controllability_campaigns.md§9.7 (private repository)
Not exported yet: no trajectory is shown in its place. - C2Pending
Stiction on LCV-102: tuning attenuates, it does not repair
EXPLORATORY1 seedSynthetic, uncalibrated- Question
- With stiction on LCV-102 (S 3 %, J 1 %, Choudhury et al. 2005), how do the deployed PID, M6 B and c2simc behave over a 1 h hold?
- Compared
- The deployed PID, M6 B and c2simc at the center scenario, seed 7100, LCV-102 stiction armed at the start of the hold.
Exploratory, one seed. The deployed PID leaves the band; M6 B stays in band with a sustained stick-slip cycle; c2simc keeps the cycle smallest. No tuning removes it.
Source and method
eng_dacs/docs/simulation/controllability_campaigns.md§9.7 (private repository)eng_dacs/docs/simulation/controllability_campaigns.md§9.5 (private repository)
Not exported yet: no trajectory is shown in its place. - Pending
Operating envelope of the nominal plant
EXPLORATORY1 seedSynthetic, uncalibrated- Question
- Under which operating conditions does the nominal installation work, and which constraint bounds each frontier?
- Compared
- 40 simulated scenarios of the stage-1 pilot (center, one-at-a-time and Latin hypercube), each with its outcome and dominant constraint.
Source and method
eng_dacs/docs/simulation/operating_envelope.md§11 (private repository)eng_dacs/docs/simulation/operating_envelope.md§5 (private repository)
Not exported yet: no trajectory is shown in its place. - Pending
Time-evolving wells (campaign D)
- Question
- How do the controllers handle a declining reservoir pressure, a rising water cut or a rising GOR over a 2 h hold?
- Compared
- Four controllers under three prescribed trajectories. The dataset exists locally but is not yet listed in the publication policy.
Not exported yet: no trajectory is shown in its place. - Not publishable
Field-calibrated well cases
- Question
- Do the conclusions hold on wells calibrated against field measurements?
- Compared
- No field-calibrated case exists in the study: every scenario is synthetic. The field operating points behind the well presets are not published.
This material cannot be published.
New to separator control? Start with the training course
Research and simulator: Marcos Esteban Soto (eng_dacs, doctoral research). Replays exported offline under a publication policy.